The beam-beam interaction is one of the dominant sources of emittance growth and luminosity lifetime deterioration. A current carrying wire has been proposed to compensate long-range beam-beam effects in the LHC and strong localized long-range beam-beam effects are experimentally investigated in the RHIC collider. Tune shift, beam transfer function, and beam loss rate are measured in dedicated experiments. In this paper, we report on simulations to study the effect of beam-wire interactions based on diffusive apertures, beam loss rates, and beam transfer function using a parallelized weak-strong beam simulation code (bbsimc). The simulation results are compared with measurements performed in RHIC during 2007 and 2008.
The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory has been in operation since 2000. Over the past decade, the luminosity in the polarized proton (p-p) operations has increased by more than one order of magnitude. The maximum total beam-beam tune shift with two collisions has reached 0.018. The beam-beam interaction leads to large tune spread, emittance growth, and short beam and luminosity lifetimes. In this article, we review the beam-beam observations during the previous RHIC p-p runs. The mechanism for particle loss is presented. The intra-beam scattering (IBS) co…
To compensate the large beam-beam tune spread and beam-beam resonance driving terms in the polarized proton operation in the Relativistic Heavy Ion Collider (RHIC), we will introduce a low-energy DC electron beam into each ring to collide head-on with the opposing proton beam. The device to provide the electron beam is called an electron lens. In this article, using a 6-D weak-strong-beam-beam interaction simulation model, we investigate the effects of head-on beam-beam compensation with electron lenses on the proton beam dynamics in the RHIC 250 GeV polarized proton operation. This article is…
In polarized proton operation, the performance of the Relativistic Heavy Ion Collider (RHIC) is limited by the head-on beam-beam effect. To overcome this limitation, two electron lenses are under commissioning. We give an overview of head-on beam-beam compensation in general and in the specific design for RHIC, which is based on electron lenses. The status of installation and commissioning are presented along with plans for the future.
During low-energy operations below the regular injection energy in the Relativistic Heavy Ion Collider (RHIC), significant beam lifetime reductions due to the beam-beam interaction in conjunction with large space charge tune shifts have been observed. We report on dedicated experiments aimed at understanding this phenomenon as well as preliminary simulation results, and propose alternative working points to improve the beam lifetime in future lowenergy RHIC runs.
We report a study of spin dynamics based on simulations with the Polymorphic Tracking Code (PTC), exploring the dependence of the static polarization limit on various beam parameters and lattice settings for a practical RHIC lattice.
To improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, the Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL. The Linac of LEReC is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with rms dp/p less than 5e-4. A 704 MHz superconducting radio frequency (SRF) booster cavity in this Linac provides up to 2.2 MeV accelerating voltage. With such a low energy and very demanding energy spread requirement, control of Higher Order Modes (HOMs) in the cavities becomes critical and needs to be carefully evaluated to ensure minimum impact on the b…
Initial simulations investigating using the RHIC-EIC proton beam as the drive beam in a plasma wakefield acceleration experiment are presented. The proton beam enters the plasma and undergoes self-modulation, forming a series of microbunches. These microbunches resonantly drive electron density perturbations within the plasma, exciting a longitudinal electric field with accelerating gradients in excess of $\mathrm{GVm^{-1}}$. Injecting electrons into the resulting wakefield offers an efficient method for accelerating electron bunches for use in the proposed EIC collider.
Current wires are considered for compensation of long-range beam-beam interactions for the High Luminosity upgrade (HL-LHC) of the Large Hadron Collider at CERN. In this note, we demonstrate the advantage of using Electron Lens for this purpose instead of a conventional current-bearing wire.
The Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL to improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon. The linac of LEReC consists of a DC photoemission gun, one 704 MHz superconducting radio frequency (SRF) booster cavity, and three normal conducting cavities. It is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with peak-to-peak momentum spread dp/p of less than 7e4. Two of the three normal conducting cavities will be used in LEReC for energy spread correction. A single-cell 704 MHz cavity for energy de-chirping and a three-c…
An accurate calibration of the luminosity measurement of the 2012 Uranium-Uranium RHIC run at 96 GeV per beam is of the greatest importance in order to measure the total uranium-uranium cross section with a reasonably small error bar. During the run, which lasted from April 20th to May 15th 2012, three vernier scans per experiment were performed. Beam intensities of up to 3.4 10$^{10}$ Uranium ions in one ring were successfully accelerated to flattop at $γ= 103.48$ corresponding to 96 GeV/beam. The desired model $β^*$ value was 0.7 m in the two low beta Interaction Points IP6 and IP8. With the…
This document presents in detail the derivation of the formulas that describe the resonance driving terms and the tune spread with amplitude generated by the beam-beam long range interactions and the DC wire compensators in cyclical machines. This analysis make use of the weak-strong approximation.
A highly efficient, fully parallelized, six-dimensional tracking model for simulating interactions of colliding hadron beams in high energy ring colliders and simulating schemes for mitigating their effects is described. The model uses the weak-strong approximation for calculating the head-on interactions when the test beam has lower intensity than the other beam, a look-up table for the efficient calculation of long-range beam-beam forces, and a self-consistent Poisson solver when both beams have comparable intensities. A performance test of the model in a parallel environment is presented. T…
A Post Mortem System was developed for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory to provide a playback of the collider state at the time of a beam abort, quench, or other failure event. Post Mortem data is used to provide diagnostics about the failure and to improve future stores. This data is read from hardware buffers and is written directly to the main file system by Accelerator Device Objects in the front-end computers. The Post Mortem System has facilitated analysis of loss monitor and power supply data, such as beam loss during magnet quenches, dump kicker mis…
The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are ex=1.3x10-9 m.rad, ey=1.7x10-11 m.rad with 2x109 electrons/bunch intensity and 1.3GeV energy. The wire scanners scan the beam by a tungsten wire with beam repetition 0.78Hz. The scanning speed is, however, very slow(~500um/sec). Since the extracted beam is quite stable by using the double kicker system, precision of the size measurement is less than 2um for 50 - 150um h…
A new system used for monitoring energetic Coulomb-scattered electrons as the main diagnostic for accurately aligning the electron and ion beams in the new Relativistic Heavy Ion Collider (RHIC) electron lenses is described in detail. The theory of electron scattering from relativistic ions is developed and applied to the design and implementation of the system used to achieve and maintain the alignment. Commissioning with gold and 3He beams is then described as well as the successful utilization of the new system during the 2015 RHIC polarized proton run. Systematic errors of the new method a…
The method for measurement of transverse profile (emittance) of the bunch by detecting of radiation arising scattering at of the bunch on the scanning wire is wide-spread. In this work the information about scattering bunch is proposed to measure using the oscillation frequency of the tightened scanning wire. In such way the system of radiation (or secondary particles) extraction and measurement can be removed. Dependence of oscillations frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam, influence of beam sel…
Current bearing wire compensators were successfully used in the 2005-2006 run of the DAΦNE collider to mitigate the detrimental effects of parasitic beam-beam interactions. A marked improvement of the positron beam lifetime was observed in machine operation with the KLOE detector. In view of the possible application of wire beam-beam compensators for the High Luminosity LHC upgrade, we revisit the DAΦNE experiments. We use an improved model of the accelerator with the goal to validate the modern simulation tools and provide valuable input for the LHC upgrade project.
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
A beam line is built after the IHEP RFQ for halo study. To determine transverse emittance and ellipse parameters of the RFQ output beam, beam size data obtained from the first two of 14 wire scanners are employed. By using the transfer matrix method and the least square method, a set of linear equations were set up and solved. The solutions were then applied as initial beam parameters in multi-particle simulations to check the method of calculation. It is shown that difference between the simulated RMS beam size and the measured one at the measurement location is less than 7%, which is accepta…
Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced acceleration experiments. Dielectric laser accelerators or plasma accelerators with external injection indeed require beam sizes at the micron level and below. We present a method using nano-fabricated metallic wires oriented at different angles to obtain projections of the transverse phase space by scanning the wires through the beam and detecting the amount of…
We report the first observations of beam losses due to bound-free pair production at the interaction point of a heavy-ion collider. This process is expected to be a major luminosity limit for the Large Hadron Collider (LHC) when it operates with 208Pb82+ ions because the localized energy deposition by the lost ions may quench superconducting magnet coils. Measurements were performed at the Relativistic Heavy Ion Collider (RHIC) during operation with 100 GeV/nucleon 63Cu29+ ions. At RHIC, the rate, energy and magnetic field are low enough so that magnet quenching is not an issue. The hadronic s…
We have studied the time evolution of the heavy ion luminosity and bunch intensities in the Relativistic Heavy Ion Collider (RHIC), at BNL, and in the Large Hadron Collider (LHC), at CERN. First, we present measurements from a large number of RHIC stores (from Run 7), colliding 100 GeV/nucleon Au beams without stochastic cooling. These are compared with two different calculation methods. The first is a simulation based on multi-particle tracking taking into account collisions, intrabeam scattering, radiation damping, and synchrotron and betatron motion. In the second, faster, method, a system …
A new approach to the technique of scanning by wires is developed. Novelty of the method is that the wire heating quantity is used as a source of information about the number of interacting particles. To increase the accuracy and sensitivity of measurements the wire heating measurement is regenerated as a change of wire natural oscillations frequency. By the rigid fixing of the wire ends on the base an unprecedented sensitivity of the frequency to the temperature and to the corresponding flux of colliding particles. The range of used frequencies (tens of kHz) and speed of processes of heat tra…