表面修饰的硅纳米通道用于尿素传感
Surface modified silicon nanochannel for urea sensing
摘要:
硅纳米线已被表面功能化的酶尿素酶的生物传感器应用,以检测和定量尿素浓度。该器件是从绝缘体上硅(SOI)晶片与自顶向下光刻方法的纳米制造。硅纳米线的微分电导可以使用源漏偏置电压来调节以获得最佳性能,并且在低浓度下对尿素敏感。实验结果表明,在0.1至0.68 mM的范围内,表面电位变化和尿素浓度之间的线性关系。我们的设备的灵敏度随时间和不同的测量条件下显示出高的再现性。纳米线尿素生物传感器提供了高质量,可重复使用的酶传感器阵列集成与硅基电路的可能性。
英文摘要:
Silicon nanowires have been surface functionalized with the enzyme urease for biosensor applications to detect and quantify urea concentration. The device is nanofabricated from a silicon on insulator (SOI) wafer with a top down lithography approach. The differential conductance of silicon nanowires can be tuned for optimum performance using the source drain bias voltage, and is sensitive to urea at low concentration. The experimental results show a linear relationship between surface potential change and urea concentration in the range of 0.1 to 0.68 mM. The sensitivity of our devices shows high reproducibility with time and different measurement conditions. The nanowire urea biosensor offers the possibility of high quality, reusable enzyme sensor array integration with silicon based circuits.