arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0802.1443nucl-ex
收藏

CERES/NA45径向漂移时间投影室

The CERES/NA45 Radial Drift Time Projection Chamber

The CERES Collaboration

摘要:

介绍了第一台径向漂移时间投影室(TPC)的设计、标定和性能。TPC是在90年代后期在CERN SPS的CERES/NA 45实验中建造和安装的,目的是提高光谱仪的动量分辨率。升级后的实验在1999年和2000年两次采集数据。在详细研究了残余畸变之后,获得了方位角上340 μ m和径向上640 μ m的空间分辨率,对应于Dp/p = sqrt{(1% * p/GeV)^2 +(2%)^2}的动量分辨率。

英文摘要:

The design, calibration, and performance of the first radial drift Time Projection Chamber (TPC) are presented. The TPC was built and installed at the CERES/NA45 experiment at the CERN SPS in the late nineties, with the objective to improve the momentum resolution of the spectrometer. The upgraded experiment took data twice, in 1999 and in 2000. After a detailed study of residual distortions a spatial resolution of 340 um in the azimuthal and 640 um in the radial direction was achieved, corresponding to a momentum resolution of Dp/p = sqrt{(1% * p/GeV)^2 + (2%)^2}.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑