低温干涉引力波探测器低温恒温器金属屏蔽管内热辐射传导效应

Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector

Takayuki Tomaru, Masao Tokunari, Kazuaki Kuroda, Takashi Uchiyama, Akira Okutomi, Masatake Ohashi, Hiroyuki Kirihara, Nobuhiro Kimura, Yoshio Saito, Nobuaki Sat… 展开作者

Takayuki Tomaru, Masao Tokunari, Kazuaki Kuroda, Takashi Uchiyama, Akira Okutomi, Masatake Ohashi, Hiroyuki Kirihara, Nobuhiro Kimura, Yoshio Saito, Nobuaki Sato, Takakazu Shintomi, Toshikazu Suzuki, Tomiyoshi Haruyama, Shinji Miyoki, Kazuhiro Yamamoto, Akira Yamamoto

摘要:

在低温干涉型引力波探测器样机的低温恒温器冷却试验中,观测到金属屏蔽管的热辐射引起的大的热负荷。热负荷大约是Stefan-Boltzmann定律计算值的1000倍。通过模拟和实验研究发现,这是由于热辐射在金属屏蔽管内的传导引起的。

英文摘要:

A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.