长时间稳定的HTSC DC-SQUID梯度计,采用二氧化硅钝化,用于超导通量Transformers测量
Long-time stable HTSC DC-SQUID gradiometers with silicon dioxide passivation for measurements with superconducting flux transformers
摘要:
在高Tc超导DC-SQUID的应用中,如生物磁学,无损评估和磁性纳米颗粒的弛豫,重要的是在延长的时间段内保持可靠的传感器性能。我们设计并制作了基于YBCO薄膜的DC-SQUID梯度计,该梯度计与磁通Transformer电感耦合以实现更高的灵敏度。该梯度仪的保护免受环境大气和湿度的SiO2和非晶YBCO层。倒装芯片配置的传感器的噪声特性,特别是在无屏蔽的环境中,示出。我们提出了一个比较的TBCCO薄膜缓冲蓝宝石或LaAlO 3衬底上的磁通Transformer在屏蔽和非屏蔽环境。在LaAlO 3磁通Transformer上使用TBCCO,我们达到了72 fT/(cm sqrt(Hz))的低白场梯度噪声。在一年的时间内测量了梯度计的电性能(临界电流IC、正常状态电阻RN和传递函数VPhi),没有显示出明显的退化迹象。
英文摘要:
In applications for high-Tc superconducting DC-SQUIDs such as biomagnetism, nondestructive evaluation and the relaxation of magnetic nanoparticles, it is important to maintain reliable sensor performance over an extended time period. We designed and produced DC-SQUID gradiometers based on YBCO thin films which are inductively coupled to a flux transformer to achieve a higher sensitivity. The gradiometers are protected against ambient atmosphere and humidity by SiO2 and amorphous YBCO layers. The noise properties of the sensor in flip-chip configuration, especially in unshielded environments, are shown. We present a comparison of TBCCO thin films on buffered sapphire or LaAlO3 substrates for the flux transformer in shielded and unshielded environments. We reach a low white field gradient noise of 72 fT/(cm sqrt(Hz)) with the TBCCO on LaAlO3 flux transformer. The electric properties of the gradiometers (critical current IC, normal state resistance RN and the transfer function VPhi) were measured over a period of one year and do not show significant signs of degradation.