arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0704.2881gr-qc
收藏

日本探测器的现状

Current status of Japanese detectors

Daisuke Tatsumi, Ryutaro Takahashi, Koji Arai, Noriyasu Nakagawa, Kazuhiro Agatsuma, Toshitaka Yamazaki, Mitsuhiro Fukushima, Masa-Katsu Fujimoto, Akiteru Takam… 展开作者

Daisuke Tatsumi, Ryutaro Takahashi, Koji Arai, Noriyasu Nakagawa, Kazuhiro Agatsuma, Toshitaka Yamazaki, Mitsuhiro Fukushima, Masa-Katsu Fujimoto, Akiteru Takamori, Alessandro Bertolini, Virginio Sannibale, Riccardo DeSalvo, Szabolcs Marka, Masaki Ando, Kimio Tsubono, Tomomi Akutsu, Kazuhiro Yamamoto, Hideki Ishitsuka, Takashi Uchiyama, Shinji Miyoki, Masatake Ohashi, Kazuaki Kuroda, Norichika Awaya, Nobuyuki Kanda, Akito Araya, Souichi Telada, Takayuki Tomaru, Tomiyoshi Haruyama, Akira Yamamoto, Nobuaki Sato, Toshitaka Suzuki, Takakazu Shintomi

摘要:

本文报道了日本TAMA和CLIO探测器的现状。正在为大型低温引力波望远镜研制这两个干涉引力波探测器,该望远镜是今后每年至少探测一次引力波信号的计划。在2004年最后一次观测实验后,TAMA 300正在升级,以提高低频区的灵敏度。为了减少地震噪音,我们正在为四个测试质量安装新的地震隔离系统,称为TAMA地震衰减系统。我们证实了稳定的质量锁腔和改进的长度和角起伏,通过使用两个SAS。我们目前正在优化第三和第四个SAS的性能。我们继续进行TAMA 300的操作和LCGT研发研究。计划在2007年夏天收集下一次数据。CLIO是一个基线长度为100米的原型探测器,用于研究低温条件下的干涉仪性能。CLIO的主要特点是它位于神冈地下,以降低地震噪声水平,并采用低温蓝宝石镜以降低热噪声水平。2006年2月成功演示了低温干涉仪的首次运行。室温下的电流灵敏度接近目标灵敏度,在4倍以内。在室温下进行了几次观测实验。一旦位移噪声达到室温的热噪声水平,应证明通过冷却测试质量镜对其的改善。

英文摘要:

Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year. TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last observation experiment in 2004. To reduce the seismic noises, we are installing new seismic isolation system, which is called TAMA Seismic Attenuation System, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for LCGT. Next data taking in the summer of 2007 is planned. CLIO is a 100-m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates Kamioka underground site for low seismic noise level, and adopts cryogenic Sapphire mirrors for low thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February of 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observation experiments at room temperature have been done. Once the displacement noise reaches at thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑